thermal: rockchip: fixes the conversion table

As Ayaka reported the thermal was abormal on rk3288 at booting time.
thermal thermal_zone1: critical temperature reached(125 C),shutting down
thermal thermal_zone2: critical temperature reached(125 C),shutting down
thermal thermal_zone1: critical temperature reached(125 C),shutting down
thermal thermal_zone2: critical temperature reached(125 C),shutting down
...
The root caused by reading the invald analogic value, the value is zero
will convert the 125 degree to trigger the critical temperature.
Fixes it with insteading of the incorrect reading now.

Fixes commit cadf29dc2a8bcaae83
("thermal: rockchip: optimize the conversion table")

Reported-by: ayaka <ayaka@soulik.info>
Signed-off-by: Caesar Wang <wxt@rock-chips.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Caesar Wang 8 년 전
부모
커밋
db8318865e
1개의 변경된 파일1개의 추가작업 그리고 1개의 파일을 삭제
  1. 1 1
      drivers/thermal/rockchip_thermal.c

+ 1 - 1
drivers/thermal/rockchip_thermal.c

@@ -464,7 +464,7 @@ static int rk_tsadcv2_code_to_temp(const struct chip_tsadc_table *table,
 	switch (table->mode) {
 	case ADC_DECREMENT:
 		code &= table->data_mask;
-		if (code < table->id[high].code)
+		if (code <= table->id[high].code)
 			return -EAGAIN;		/* Incorrect reading */
 
 		while (low <= high) {