浏览代码

ab8500-chargalg: Update battery health on safety timer exp

When the charging safety timer elapses, the battery health is
shown as "Good". This is misleading and also makes it difficult
to distinguish issues relating to discharging despite the fact
that the charger is still connected.

When in actual fact a safety timer elapse is an indication of a
fault in the battery. Here we make this clearer by reporting
POWER_SUPPLY_HEALTH_UNSPEC_FAILURE instead.

Signed-off-by: Lee Jones <lee.jones@linaro.org>
Lee Jones 12 年之前
父节点
当前提交
d80108fc69
共有 1 个文件被更改,包括 3 次插入0 次删除
  1. 3 0
      drivers/power/abx500_chargalg.c

+ 3 - 0
drivers/power/abx500_chargalg.c

@@ -1628,6 +1628,9 @@ static int abx500_chargalg_get_property(struct power_supply *psy,
 				val->intval = POWER_SUPPLY_HEALTH_COLD;
 			else
 				val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
+		} else if (di->charge_state == STATE_SAFETY_TIMER_EXPIRED ||
+			   di->charge_state == STATE_SAFETY_TIMER_EXPIRED_INIT) {
+			val->intval = POWER_SUPPLY_HEALTH_UNSPEC_FAILURE;
 		} else {
 			val->intval = POWER_SUPPLY_HEALTH_GOOD;
 		}