staging: comedi: pcmuio: fix types of some private data variables

The 'enabled_mask' is a bit mask of the channels that are enabled
for interrupt detection and should be an unsigned int.

The 'stop_count' is a >= 0 value that is set by the unsigned int
cmd->stop_arg. Make it an unsigned int.

The 'active' and 'continuous' members are flags. Make them unsigned
int bit-fields to save a bit of space.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Cc: Ian Abbott <abbotti@mev.co.uk>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
H Hartley Sweeten 11 anni fa
parent
commit
d5f81755d6
1 ha cambiato i file con 4 aggiunte e 4 eliminazioni
  1. 4 4
      drivers/staging/comedi/drivers/pcmuio.c

+ 4 - 4
drivers/staging/comedi/drivers/pcmuio.c

@@ -130,10 +130,10 @@ static const struct pcmuio_board pcmuio_boards[] = {
 struct pcmuio_asic {
 	spinlock_t pagelock;	/* protects the page registers */
 	spinlock_t spinlock;	/* protects member variables */
-	int enabled_mask;
-	int active;
-	int stop_count;
-	int continuous;
+	unsigned int enabled_mask;
+	unsigned int stop_count;
+	unsigned int active:1;
+	unsigned int continuous:1;
 };
 
 struct pcmuio_private {