@@ -0,0 +1,39 @@
|
|
|
|
+* Renesas R-Car Multi-Function Timer Pulse Unit 2 (MTU2)
|
|
|
|
+
|
|
|
|
+The MTU2 is a multi-purpose, multi-channel timer/counter with configurable
|
|
|
|
+clock inputs and programmable compare match.
|
|
|
|
+
|
|
|
|
+Channels share hardware resources but their counter and compare match value
|
|
|
|
+are independent. The MTU2 hardware supports five channels indexed from 0 to 4.
|
|
|
|
+
|
|
|
|
+Required Properties:
|
|
|
|
+
|
|
|
|
+ - compatible: must contain "renesas,mtu2"
|
|
|
|
+
|
|
|
|
+ - reg: base address and length of the registers block for the timer module.
|
|
|
|
+
|
|
|
|
+ - interrupts: interrupt specifiers for the timer, one for each entry in
|
|
|
|
+ interrupt-names.
|
|
|
|
+ - interrupt-names: must contain one entry named "tgi?a" for each enabled
|
|
|
|
+ channel, where "?" is the channel index expressed as one digit from "0" to
|
|
|
|
+ "4".
|
|
|
|
+
|
|
|
|
+ - clocks: a list of phandle + clock-specifier pairs, one for each entry
|
|
|
|
+ in clock-names.
|
|
|
|
+ - clock-names: must contain "fck" for the functional clock.
|
|
|
|
+
|
|
|
|
+
|
|
|
|
+Example: R7S72100 (RZ/A1H) MTU2 node
|
|
|
|
+
|
|
|
|
+ mtu2: timer@fcff0000 {
|
|
|
|
+ compatible = "renesas,mtu2";
|
|
|
|
+ reg = <0xfcff0000 0x400>;
|
|
|
|
+ interrupts = <0 139 IRQ_TYPE_LEVEL_HIGH>,
|
|
|
|
+ <0 146 IRQ_TYPE_LEVEL_HIGH>,
|
|
|
|
+ <0 150 IRQ_TYPE_LEVEL_HIGH>,
|
|
|
|
+ <0 154 IRQ_TYPE_LEVEL_HIGH>,
|
|
|
|
+ <0 159 IRQ_TYPE_LEVEL_HIGH>;
|
|
|
|
+ interrupt-names = "tgi0a", "tgi1a", "tgi2a", "tgi3a", "tgi4a";
|
|
|
|
+ clocks = <&mstp3_clks R7S72100_CLK_MTU2>;
|
|
|
|
+ clock-names = "fck";
|
|
|
|
+ };
|