signal/sparc: Document a conflict with SI_USER with SIGFPE

Setting si_code to __SI_FAULT results in a userspace seeing
an si_code of 0.  This is the same si_code as SI_USER.  Posix
and common sense requires that SI_USER not be a signal specific
si_code.  As such this use of 0 for the si_code is a pretty
horribly broken ABI.

This was introduced in 2.3.41 so this mess has had a long time for
people to be able to start depending on it.

As this bug has existed for 17 years already I don't know if it is
worth fixing.  It is definitely worth documenting what is going
on so that no one decides to copy this bad decision.

Cc: "David S. Miller" <davem@davemloft.net>
Cc: sparclinux@vger.kernel.org
Signed-off-by: "Eric W. Biederman" <ebiederm@xmission.com>
Eric W. Biederman 8 年之前
父节点
当前提交
cc9f72e474
共有 3 个文件被更改,包括 9 次插入2 次删除
  1. 7 0
      arch/sparc/include/uapi/asm/siginfo.h
  2. 1 1
      arch/sparc/kernel/traps_32.c
  3. 1 1
      arch/sparc/kernel/traps_64.c

+ 7 - 0
arch/sparc/include/uapi/asm/siginfo.h

@@ -16,6 +16,13 @@
 
 #define SI_NOINFO	32767		/* no information in siginfo_t */
 
+/*
+ * SIGFPE si_codes
+ */
+#ifdef __KERNEL__
+#define FPE_FIXME	(__SI_FAULT|0)	/* Broken dup of SI_USER */
+#endif /* __KERNEL__ */
+
 /*
  * SIGEMT si_codes
  */

+ 1 - 1
arch/sparc/kernel/traps_32.c

@@ -306,7 +306,7 @@ void do_fpe_trap(struct pt_regs *regs, unsigned long pc, unsigned long npc,
 	info.si_errno = 0;
 	info.si_addr = (void __user *)pc;
 	info.si_trapno = 0;
-	info.si_code = __SI_FAULT;
+	info.si_code = FPE_FIXME;
 	if ((fsr & 0x1c000) == (1 << 14)) {
 		if (fsr & 0x10)
 			info.si_code = FPE_FLTINV;

+ 1 - 1
arch/sparc/kernel/traps_64.c

@@ -2258,7 +2258,7 @@ static void do_fpe_common(struct pt_regs *regs)
 		info.si_errno = 0;
 		info.si_addr = (void __user *)regs->tpc;
 		info.si_trapno = 0;
-		info.si_code = __SI_FAULT;
+		info.si_code = FPE_FIXME;
 		if ((fsr & 0x1c000) == (1 << 14)) {
 			if (fsr & 0x10)
 				info.si_code = FPE_FLTINV;