Pārlūkot izejas kodu

i40evf: don't shut down admin queue on error

If the driver encounters an error while communicating with the PF
driver,  don't just shut down the admin queue unconditionally. The PF
may be delayed, and shutting down the admin queue causes it to fail
completely. If this happens, the VF will never complete initialization.

Change-ID: I6192e9d8caeefb738428c3597fa2f54fa400ce7f
Signed-off-by: Mitch Williams <mitch.a.williams@intel.com>
Signed-off-by: Catherine Sullivan <catherine.sullivan@intel.com>
Tested-by: Sibai Li <sibai.li@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Mitch Williams 11 gadi atpakaļ
vecāks
revīzija
c89a9e00f9
1 mainītis faili ar 0 papildinājumiem un 2 dzēšanām
  1. 0 2
      drivers/net/ethernet/intel/i40evf/i40evf_main.c

+ 0 - 2
drivers/net/ethernet/intel/i40evf/i40evf_main.c

@@ -2133,8 +2133,6 @@ err_alloc:
 	kfree(adapter->vf_res);
 	adapter->vf_res = NULL;
 err:
-	if (hw->aq.asq.count)
-		i40evf_shutdown_adminq(hw); /* ignore error */
 	/* Things went into the weeds, so try again later */
 	if (++adapter->aq_wait_count > I40EVF_AQ_MAX_ERR) {
 		dev_err(&pdev->dev, "Failed to communicate with PF; giving up.\n");