Ver Fonte

ARM: ux500: Fix SSP register address format

SSP won't probe unless the specified register address format
is correct i.e. we have to specify that the address is in hex.
After this patch has been applied, the SSP (SPI) driver probes
as expected.

Acked-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Lee Jones há 13 anos atrás
pai
commit
c164fa62b9
1 ficheiros alterados com 1 adições e 1 exclusões
  1. 1 1
      arch/arm/boot/dts/dbx5x0.dtsi

+ 1 - 1
arch/arm/boot/dts/dbx5x0.dtsi

@@ -536,7 +536,7 @@
 
 
 		ssp@80002000 {
 		ssp@80002000 {
 			compatible = "arm,pl022", "arm,primecell";
 			compatible = "arm,pl022", "arm,primecell";
-			reg = <80002000 0x1000>;
+			reg = <0x80002000 0x1000>;
 			interrupts = <0 14 0x4>;
 			interrupts = <0 14 0x4>;
 			#address-cells = <1>;
 			#address-cells = <1>;
 			#size-cells = <0>;
 			#size-cells = <0>;