浏览代码

thermal: imx: pass cpu_present_mask to cpufreq_cooling_register()

cpufreq_cooling_register() expects mask of all the CPUs where frequency
constraint is applicable.

This platform has more than one CPU to which these constraints will apply and so
passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a
single cluster of CPUs and the constraint applies to all CPUs.

If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework
isn't aware of any siblings sharing clock line.

Fix it by passing cpu_present_mask to cpufreq_cooling_register().

Cc: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Viresh Kumar 10 年之前
父节点
当前提交
bec85d2e0c
共有 1 个文件被更改,包括 1 次插入3 次删除
  1. 1 3
      drivers/thermal/imx_thermal.c

+ 1 - 3
drivers/thermal/imx_thermal.c

@@ -453,7 +453,6 @@ static int imx_thermal_probe(struct platform_device *pdev)
 	const struct of_device_id *of_id =
 		of_match_device(of_imx_thermal_match, &pdev->dev);
 	struct imx_thermal_data *data;
-	struct cpumask clip_cpus;
 	struct regmap *map;
 	int measure_freq;
 	int ret;
@@ -511,8 +510,7 @@ static int imx_thermal_probe(struct platform_device *pdev)
 	regmap_write(map, MISC0 + REG_SET, MISC0_REFTOP_SELBIASOFF);
 	regmap_write(map, TEMPSENSE0 + REG_SET, TEMPSENSE0_POWER_DOWN);
 
-	cpumask_set_cpu(0, &clip_cpus);
-	data->cdev = cpufreq_cooling_register(&clip_cpus);
+	data->cdev = cpufreq_cooling_register(cpu_present_mask);
 	if (IS_ERR(data->cdev)) {
 		ret = PTR_ERR(data->cdev);
 		dev_err(&pdev->dev,