浏览代码

regulator: ti-abb: skip optional parameter for ldo-address

On platforms like OMAP4460, LDO override is never used. Even though
efuse determines the ABB bias mode to operate at, ABB voltage is
preconfigured in internal efuse registers without the need for
LDO override for bias voltage. So skip optional parameter if
property is not present.

Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
Nishanth Menon 12 年之前
父节点
当前提交
bde251a9a8
共有 1 个文件被更改,包括 5 次插入0 次删除
  1. 5 0
      drivers/regulator/ti-abb-regulator.c

+ 5 - 0
drivers/regulator/ti-abb-regulator.c

@@ -765,6 +765,11 @@ static int ti_abb_probe(struct platform_device *pdev)
 
 	pname = "ldo-address";
 	res = platform_get_resource_byname(pdev, IORESOURCE_MEM, pname);
+	if (!res) {
+		dev_dbg(dev, "Missing '%s' IO resource\n", pname);
+		ret = -ENODEV;
+		goto skip_opt;
+	}
 	abb->ldo_base = devm_ioremap_resource(dev, res);
 	if (IS_ERR(abb->ldo_base)) {
 		ret = PTR_ERR(abb->ldo_base);