ath9k: Fix NoA start time calculation

The start time field in the NoA attribute needs to be
updated based on the TSF timer when an absence notification
is sent by the P2P GO. When two channel contexts are active,
continuous, cyclic NoA is announced by setting the count value to 255,
but the start time is updated only once, for one beacon and
the same value is sent in all subsequent beacons, even
though the timestamp keeps moving.

Fix this by removing the check for 'periodic_noa_duration'
and assign the interface's start_time/duration values directly
when there is more than one active context.

Signed-off-by: Sujith Manoharan <c_manoha@qca.qualcomm.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
Sujith Manoharan 11 years ago
parent
commit
bd81533dbd
1 changed files with 2 additions and 2 deletions
  1. 2 2
      drivers/net/wireless/ath/ath9k/channel.c

+ 2 - 2
drivers/net/wireless/ath/ath9k/channel.c

@@ -377,13 +377,13 @@ void ath_chanctx_event(struct ath_softc *sc, struct ieee80211_vif *vif,
 		    tsf_time - avp->periodic_noa_start > BIT(30))
 			avp->periodic_noa_duration = 0;
 
-		if (ctx->active && !avp->periodic_noa_duration) {
+		if (ctx->active) {
 			avp->periodic_noa_start = tsf_time;
 			avp->periodic_noa_duration =
 				TU_TO_USEC(cur_conf->beacon_interval) / 2 -
 				sc->sched.channel_switch_time;
 			noa_changed = true;
-		} else if (!ctx->active && avp->periodic_noa_duration) {
+		} else if (!ctx->active) {
 			avp->periodic_noa_duration = 0;
 			noa_changed = true;
 		}