MIPS: ralink: Remove check for CONFIG_PCI on non-PCI SoCs

The code currently panics if PCI is enabled but the SoC has no PCI bus.
This check is superfluous as the driver only loads if enabled in the
devicetree.

Signed-off-by: John Crispin <blogic@openwrt.org>
Cc: linux-mips@linux-mips.org
Patchwork: https://patchwork.linux-mips.org/patch/11444/
Signed-off-by: Ralf Baechle <ralf@linux-mips.org>
John Crispin 9 lat temu
rodzic
commit
bc19f5d677
1 zmienionych plików z 0 dodań i 3 usunięć
  1. 0 3
      arch/mips/ralink/mt7620.c

+ 0 - 3
arch/mips/ralink/mt7620.c

@@ -535,9 +535,6 @@ void prom_soc_init(struct ralink_soc_info *soc_info)
 			ralink_soc = MT762X_SOC_MT7620N;
 			name = "MT7620N";
 			soc_info->compatible = "ralink,mt7620n-soc";
-#ifdef CONFIG_PCI
-			panic("mt7620n is only supported for non pci kernels");
-#endif
 		}
 	} else if (n0 == MT7620_CHIP_NAME0 && n1 == MT7628_CHIP_NAME1) {
 		u32 efuse = __raw_readl(sysc + SYSC_REG_EFUSE_CFG);