@@ -0,0 +1,38 @@
|
|
|
+TI ADC128D818 ADC System Monitor With Temperature Sensor
|
|
|
+--------------------------------------------------------
|
|
|
+
|
|
|
+Operation modes:
|
|
|
+
|
|
|
+ - Mode 0: 7 single-ended voltage readings (IN0-IN6),
|
|
|
+ 1 temperature reading (internal)
|
|
|
+ - Mode 1: 8 single-ended voltage readings (IN0-IN7),
|
|
|
+ no temperature
|
|
|
+ - Mode 2: 4 pseudo-differential voltage readings
|
|
|
+ (IN0-IN1, IN3-IN2, IN4-IN5, IN7-IN6),
|
|
|
+ 1 temperature reading (internal)
|
|
|
+ - Mode 3: 4 single-ended voltage readings (IN0-IN3),
|
|
|
+ 2 pseudo-differential voltage readings
|
|
|
+ (IN4-IN5, IN7-IN6),
|
|
|
+ 1 temperature reading (internal)
|
|
|
+
|
|
|
+If no operation mode is configured via device tree, the driver keeps the
|
|
|
+currently active chip operation mode (default is mode 0).
|
|
|
+
|
|
|
+
|
|
|
+Required node properties:
|
|
|
+
|
|
|
+ - compatible: must be set to "ti,adc128d818"
|
|
|
+ - reg: I2C address of the device
|
|
|
+
|
|
|
+Optional node properties:
|
|
|
+
|
|
|
+ - ti,mode: Operation mode (see above).
|
|
|
+
|
|
|
+
|
|
|
+Example (operation mode 2):
|
|
|
+
|
|
|
+ adc128d818@1d {
|
|
|
+ compatible = "ti,adc128d818";
|
|
|
+ reg = <0x1d>;
|
|
|
+ ti,mode = <2>;
|
|
|
+ };
|