@@ -1007,7 +1007,7 @@ static int rmi_probe(struct hid_device *hdev, const struct hid_device_id *id)
|
|
|
goto start;
|
|
|
}
|
|
|
|
|
|
- data->input_report_size = (input_report->size >> 3) + 1 /* report id */;
|
|
|
+ data->input_report_size = hid_report_len(input_report);
|
|
|
|
|
|
if (!rmi_check_valid_report_id(hdev, HID_OUTPUT_REPORT,
|
|
|
RMI_WRITE_REPORT_ID, &output_report)) {
|
|
@@ -1016,8 +1016,7 @@ static int rmi_probe(struct hid_device *hdev, const struct hid_device_id *id)
|
|
|
goto start;
|
|
|
}
|
|
|
|
|
|
- data->output_report_size = (output_report->size >> 3)
|
|
|
- + 1 /* report id */;
|
|
|
+ data->output_report_size = hid_report_len(output_report);
|
|
|
|
|
|
data->device_flags |= RMI_DEVICE;
|
|
|
alloc_size = data->output_report_size + data->input_report_size;
|