As 'reg' is unsigned, it can't be less than 0, so checking if it is greater than or equal to 0 will always result in a true condition. Signed-off-by: Lee Jones <lee.jones@linaro.org>
@@ -52,7 +52,7 @@ static const struct mfd_cell max77802_devs[] = {
static bool max77802_pmic_is_accessible_reg(struct device *dev,
unsigned int reg)
{
- return (reg >= MAX77802_REG_DEVICE_ID && reg < MAX77802_REG_PMIC_END);
+ return reg < MAX77802_REG_PMIC_END;
}
static bool max77802_rtc_is_accessible_reg(struct device *dev,