mfd: da9061: Fix to remove BBAT_CONT register from chip model

Remove the register DA9062AA_BBAT_CONT (0x0C5) from the DA9061 chip model
regmap access ranges. This applies to both da9061_aa_readable_ranges[]
and da9061_aa_writeable_ranges[].

This change is to correct the DA9061 chip model and align it with the
latest DA9061 Datasheet.

This register previously appeared in the DA9061 Datasheet, Revision 3.2,
01-Mar-2016 and has been removed from later DA9061 datasheet from Dialog,
Revision 3.3, 04-Apr-2017.

Signed-off-by: Steve Twiss <stwiss.opensource@diasemi.com>
Signed-off-by: Lee Jones <lee.jones@linaro.org>
Steve Twiss 8 роки тому
батько
коміт
b77eb79acc
1 змінених файлів з 0 додано та 6 видалено
  1. 0 6
      drivers/mfd/da9062-core.c

+ 0 - 6
drivers/mfd/da9062-core.c

@@ -644,9 +644,6 @@ static const struct regmap_range da9062_aa_readable_ranges[] = {
 	}, {
 		.range_min = DA9062AA_VLDO1_B,
 		.range_max = DA9062AA_VLDO4_B,
-	}, {
-		.range_min = DA9062AA_BBAT_CONT,
-		.range_max = DA9062AA_BBAT_CONT,
 	}, {
 		.range_min = DA9062AA_INTERFACE,
 		.range_max = DA9062AA_CONFIG_E,
@@ -723,9 +720,6 @@ static const struct regmap_range da9062_aa_writeable_ranges[] = {
 	}, {
 		.range_min = DA9062AA_VLDO1_B,
 		.range_max = DA9062AA_VLDO4_B,
-	}, {
-		.range_min = DA9062AA_BBAT_CONT,
-		.range_max = DA9062AA_BBAT_CONT,
 	}, {
 		.range_min = DA9062AA_GP_ID_0,
 		.range_max = DA9062AA_GP_ID_19,