Browse Source

clk: imx: clk-pllv3: fix incorrect handle of enet powerdown bit

After commit f53947456f98 ("ARM: clk: imx: update pllv3 to support imx7"),
the former used BM_PLL_POWER bit is not correct anymore for IMX7 ENET.
Instead, pll->powerdown holds the correct bit, so using powerdown bit
in clk_pllv3_{prepare | unprepare} functions.

Fixes: f53947456f98 ("ARM: clk: imx: update pllv3 to support imx7")
Signed-off-by: Dong Aisheng <aisheng.dong@nxp.com>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
Dong Aisheng 9 years ago
parent
commit
b3e76bdc0b
1 changed files with 4 additions and 4 deletions
  1. 4 4
      drivers/clk/imx/clk-pllv3.c

+ 4 - 4
drivers/clk/imx/clk-pllv3.c

@@ -77,9 +77,9 @@ static int clk_pllv3_prepare(struct clk_hw *hw)
 
 	val = readl_relaxed(pll->base);
 	if (pll->powerup_set)
-		val |= BM_PLL_POWER;
+		val |= pll->powerdown;
 	else
-		val &= ~BM_PLL_POWER;
+		val &= ~pll->powerdown;
 	writel_relaxed(val, pll->base);
 
 	return clk_pllv3_wait_lock(pll);
@@ -92,9 +92,9 @@ static void clk_pllv3_unprepare(struct clk_hw *hw)
 
 	val = readl_relaxed(pll->base);
 	if (pll->powerup_set)
-		val &= ~BM_PLL_POWER;
+		val &= ~pll->powerdown;
 	else
-		val |= BM_PLL_POWER;
+		val |= pll->powerdown;
 	writel_relaxed(val, pll->base);
 }