@@ -461,6 +461,15 @@ static int bq25890_power_supply_get_property(struct power_supply *psy,
|
|
|
val->intval = bq25890_find_val(bq->init_data.iterm, TBL_ITERM);
|
|
|
break;
|
|
|
|
|
|
+ case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
|
|
+ ret = bq25890_field_read(bq, F_SYSV); /* read measured value */
|
|
|
+ if (ret < 0)
|
|
|
+ return ret;
|
|
|
+
|
|
|
+ /* converted_val = 2.304V + ADC_val * 20mV (table 10.3.15) */
|
|
|
+ val->intval = 2304000 + ret * 20000;
|
|
|
+ break;
|
|
|
+
|
|
|
default:
|
|
|
return -EINVAL;
|
|
|
}
|
|
@@ -669,6 +678,7 @@ static enum power_supply_property bq25890_power_supply_props[] = {
|
|
|
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
|
|
|
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE_MAX,
|
|
|
POWER_SUPPLY_PROP_CHARGE_TERM_CURRENT,
|
|
|
+ POWER_SUPPLY_PROP_VOLTAGE_NOW,
|
|
|
};
|
|
|
|
|
|
static char *bq25890_charger_supplied_to[] = {
|