@@ -730,10 +730,13 @@ omap_bandgap_force_single_read(struct omap_bandgap *bg_ptr, int id)
|
|
|
}
|
|
|
|
|
|
/**
|
|
|
- * enable_continuous_mode() - One time enabling of continuous conversion mode
|
|
|
- * @bg_ptr - pointer to scm instance
|
|
|
+ * omap_bandgap_set_continous_mode() - One time enabling of continuous mode
|
|
|
+ * @bg_ptr: pointer to struct omap_bandgap
|
|
|
*
|
|
|
- * Call this function only if HAS(MODE_CONFIG) is set
|
|
|
+ * Call this function only if HAS(MODE_CONFIG) is set. As this driver may
|
|
|
+ * be used for junction temperature monitoring, it is desirable that the
|
|
|
+ * sensors are operational all the time, so that alerts are generated
|
|
|
+ * properly.
|
|
|
*/
|
|
|
static int omap_bandgap_set_continuous_mode(struct omap_bandgap *bg_ptr)
|
|
|
{
|