Selaa lähdekoodia

brcmfmac: Dont sleep when ctrl frames to transmit.

The SDIO watchdog will put the device in sleep mode when there is
no activity for some time and nothing to do anymore. This check
is incomplete and should also check if there is a control frame
to transmit.

Reviewed-by: Arend Van Spriel <arend@broadcom.com>
Reviewed-by: Franky (Zhenhui) Lin <frankyl@broadcom.com>
Reviewed-by: Pieter-Paul Giesberts <pieterpg@broadcom.com>
Reviewed-by: Daniel (Deognyoun) Kim <dekim@broadcom.com>
Signed-off-by: Hante Meuleman <meuleman@broadcom.com>
Signed-off-by: Arend van Spriel <arend@broadcom.com>
Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
Hante Meuleman 10 vuotta sitten
vanhempi
commit
a7b134a767
1 muutettua tiedostoa jossa 1 lisäystä ja 0 poistoa
  1. 1 0
      drivers/net/wireless/brcm80211/brcmfmac/sdio.c

+ 1 - 0
drivers/net/wireless/brcm80211/brcmfmac/sdio.c

@@ -1027,6 +1027,7 @@ brcmf_sdio_bus_sleep(struct brcmf_sdio *bus, bool sleep, bool pendok)
 			/* Don't sleep if something is pending */
 			/* Don't sleep if something is pending */
 			if (atomic_read(&bus->intstatus) ||
 			if (atomic_read(&bus->intstatus) ||
 			    atomic_read(&bus->ipend) > 0 ||
 			    atomic_read(&bus->ipend) > 0 ||
+			    bus->ctrl_frame_stat ||
 			    (!atomic_read(&bus->fcstate) &&
 			    (!atomic_read(&bus->fcstate) &&
 			    brcmu_pktq_mlen(&bus->txq, ~bus->flowcontrol) &&
 			    brcmu_pktq_mlen(&bus->txq, ~bus->flowcontrol) &&
 			    data_ok(bus))) {
 			    data_ok(bus))) {