Browse Source

iio: dht11: Improve detection of sensor type

The old code was based on a DHT11 datasheet which specifies a measurement
range of 20%-90% RH. Turns out the sensor actually reports values outside
this range, so we should support it as far as possible.

Reported-by: Edward Attfield <edward@attfield.ca>
Signed-off-by: Harald Geyer <harald@ccbib.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Harald Geyer 7 years ago
parent
commit
a6bffb6920
1 changed files with 1 additions and 1 deletions
  1. 1 1
      drivers/iio/humidity/dht11.c

+ 1 - 1
drivers/iio/humidity/dht11.c

@@ -159,7 +159,7 @@ static int dht11_decode(struct dht11 *dht11, int offset)
 	}
 
 	dht11->timestamp = ktime_get_boot_ns();
-	if (hum_int < 20) {  /* DHT22 */
+	if (hum_int < 4) {  /* DHT22: 100000 = (3*256+232)*100 */
 		dht11->temperature = (((temp_int & 0x7f) << 8) + temp_dec) *
 					((temp_int & 0x80) ? -100 : 100);
 		dht11->humidity = ((hum_int << 8) + hum_dec) * 100;