@@ -36,6 +36,10 @@ struct press_state {
|
|
|
struct hid_sensor_common common_attributes;
|
|
|
struct hid_sensor_hub_attribute_info press_attr;
|
|
|
u32 press_data;
|
|
|
+ int scale_pre_decml;
|
|
|
+ int scale_post_decml;
|
|
|
+ int scale_precision;
|
|
|
+ int value_offset;
|
|
|
};
|
|
|
|
|
|
/* Channel definitions */
|
|
@@ -102,12 +106,12 @@ static int press_read_raw(struct iio_dev *indio_dev,
|
|
|
ret_type = IIO_VAL_INT;
|
|
|
break;
|
|
|
case IIO_CHAN_INFO_SCALE:
|
|
|
- *val = press_state->press_attr.units;
|
|
|
- ret_type = IIO_VAL_INT;
|
|
|
+ *val = press_state->scale_pre_decml;
|
|
|
+ *val2 = press_state->scale_post_decml;
|
|
|
+ ret_type = press_state->scale_precision;
|
|
|
break;
|
|
|
case IIO_CHAN_INFO_OFFSET:
|
|
|
- *val = hid_sensor_convert_exponent(
|
|
|
- press_state->press_attr.unit_expo);
|
|
|
+ *val = press_state->value_offset;
|
|
|
ret_type = IIO_VAL_INT;
|
|
|
break;
|
|
|
case IIO_CHAN_INFO_SAMP_FREQ:
|
|
@@ -229,6 +233,11 @@ static int press_parse_report(struct platform_device *pdev,
|
|
|
dev_dbg(&pdev->dev, "press %x:%x\n", st->press_attr.index,
|
|
|
st->press_attr.report_id);
|
|
|
|
|
|
+ st->scale_precision = hid_sensor_format_scale(
|
|
|
+ HID_USAGE_SENSOR_PRESSURE,
|
|
|
+ &st->press_attr,
|
|
|
+ &st->scale_pre_decml, &st->scale_post_decml);
|
|
|
+
|
|
|
/* Set Sensitivity field ids, when there is no individual modifier */
|
|
|
if (st->common_attributes.sensitivity.index < 0) {
|
|
|
sensor_hub_input_get_attribute_info(hsdev,
|