Răsfoiți Sursa

amd64_edac: Fix DCT base address selector

The correct check is to verify whether in high range we're below 4GB
and not to extract the DctSelBaseAddr again. See "2.8.5 Routing DRAM
Requests" in the F10h BKDG.

Cc: <stable@kernel.org> # .32.x .33.x .34.x
Signed-off-by: Borislav Petkov <borislav.petkov@amd.com>
Acked-by: Doug Thompson <dougthompson@xmission.com>
Borislav Petkov 15 ani în urmă
părinte
comite
9975a5f22a
1 a modificat fișierele cu 1 adăugiri și 1 ștergeri
  1. 1 1
      drivers/edac/amd64_edac.c

+ 1 - 1
drivers/edac/amd64_edac.c

@@ -1435,7 +1435,7 @@ static inline u64 f10_get_base_addr_offset(u64 sys_addr, int hi_range_sel,
 	u64 chan_off;
 
 	if (hi_range_sel) {
-		if (!(dct_sel_base_addr & 0xFFFFF800) &&
+		if (!(dct_sel_base_addr & 0xFFFF0000) &&
 		   hole_valid && (sys_addr >= 0x100000000ULL))
 			chan_off = hole_off << 16;
 		else