PowerCap: Fix mode for energy counter

As per the documentation of powercap sysfs, energy_uj field is read only,
if it can't be reset. Currently it always allows write but will fail,
if there is no reset callback.
Changing mode field, to read only if there is no reset callback.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Reported-by: Dirk Brandewie <dirk.j.brandewie@intel.com>
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
Srinivas Pandruvada 11 年之前
父节点
当前提交
95677a9a38
共有 1 个文件被更改,包括 6 次插入1 次删除
  1. 6 1
      drivers/powercap/powercap_sys.c

+ 6 - 1
drivers/powercap/powercap_sys.c

@@ -377,9 +377,14 @@ static void create_power_zone_common_attributes(
 	if (power_zone->ops->get_max_energy_range_uj)
 		power_zone->zone_dev_attrs[count++] =
 					&dev_attr_max_energy_range_uj.attr;
-	if (power_zone->ops->get_energy_uj)
+	if (power_zone->ops->get_energy_uj) {
+		if (power_zone->ops->reset_energy_uj)
+			dev_attr_energy_uj.attr.mode = S_IWUSR | S_IRUGO;
+		else
+			dev_attr_energy_uj.attr.mode = S_IRUGO;
 		power_zone->zone_dev_attrs[count++] =
 					&dev_attr_energy_uj.attr;
+	}
 	if (power_zone->ops->get_power_uw)
 		power_zone->zone_dev_attrs[count++] =
 					&dev_attr_power_uw.attr;