@@ -559,9 +559,17 @@ static int i40e_set_settings(struct net_device *netdev,
|
|
config.eeer = abilities.eeer_val;
|
|
config.eeer = abilities.eeer_val;
|
|
config.low_power_ctrl = abilities.d3_lpan;
|
|
config.low_power_ctrl = abilities.d3_lpan;
|
|
|
|
|
|
- /* If link is up set link and an so changes take effect */
|
|
|
|
- if (hw->phy.link_info.link_info & I40E_AQ_LINK_UP)
|
|
|
|
- config.abilities |= I40E_AQ_PHY_ENABLE_ATOMIC_LINK;
|
|
|
|
|
|
+ /* set link and auto negotiation so changes take effect */
|
|
|
|
+ config.abilities |= I40E_AQ_PHY_ENABLE_ATOMIC_LINK;
|
|
|
|
+ /* If link is up put link down */
|
|
|
|
+ if (hw->phy.link_info.link_info & I40E_AQ_LINK_UP) {
|
|
|
|
+ /* Tell the OS link is going down, the link will go
|
|
|
|
+ * back up when fw says it is ready asynchronously
|
|
|
|
+ */
|
|
|
|
+ netdev_info(netdev, "PHY settings change requested, NIC Link is going down.\n");
|
|
|
|
+ netif_carrier_off(netdev);
|
|
|
|
+ netif_tx_stop_all_queues(netdev);
|
|
|
|
+ }
|
|
|
|
|
|
/* make the aq call */
|
|
/* make the aq call */
|
|
status = i40e_aq_set_phy_config(hw, &config, NULL);
|
|
status = i40e_aq_set_phy_config(hw, &config, NULL);
|
|
@@ -678,6 +686,13 @@ static int i40e_set_pauseparam(struct net_device *netdev,
|
|
else
|
|
else
|
|
return -EINVAL;
|
|
return -EINVAL;
|
|
|
|
|
|
|
|
+ /* Tell the OS link is going down, the link will go back up when fw
|
|
|
|
+ * says it is ready asynchronously
|
|
|
|
+ */
|
|
|
|
+ netdev_info(netdev, "Flow control settings change requested, NIC Link is going down.\n");
|
|
|
|
+ netif_carrier_off(netdev);
|
|
|
|
+ netif_tx_stop_all_queues(netdev);
|
|
|
|
+
|
|
/* Set the fc mode and only restart an if link is up*/
|
|
/* Set the fc mode and only restart an if link is up*/
|
|
status = i40e_set_fc(hw, &aq_failures, link_up);
|
|
status = i40e_set_fc(hw, &aq_failures, link_up);
|
|
|
|
|