Prechádzať zdrojové kódy

ARM: davinci: da850: add con_id for the SATA clock

The ahci-da850 SATA driver is now capable of retrieving clocks by
con_id. Add the connection id for the sysclk2-derived SATA clock.

Signed-off-by: Bartosz Golaszewski <bgolaszewski@baylibre.com>
Signed-off-by: Sekhar Nori <nsekhar@ti.com>
Bartosz Golaszewski 8 rokov pred
rodič
commit
8ba0f6caa4
1 zmenil súbory, kde vykonal 1 pridanie a 1 odobranie
  1. 1 1
      arch/arm/mach-davinci/da850.c

+ 1 - 1
arch/arm/mach-davinci/da850.c

@@ -543,7 +543,7 @@ static struct clk_lookup da850_clks[] = {
 	CLK("spi_davinci.0",	NULL,		&spi0_clk),
 	CLK("spi_davinci.1",	NULL,		&spi1_clk),
 	CLK("vpif",		NULL,		&vpif_clk),
-	CLK("ahci_da850",	NULL,		&sata_clk),
+	CLK("ahci_da850",	"fck",		&sata_clk),
 	CLK("davinci-rproc.0",	NULL,		&dsp_clk),
 	CLK(NULL,		NULL,		&ehrpwm_clk),
 	CLK("ehrpwm.0",		"fck",		&ehrpwm0_clk),