@@ -658,23 +658,32 @@ static struct class regulator_class = {
|
|
|
|
|
|
/* Calculate the new optimum regulator operating mode based on the new total
|
|
|
* consumer load. All locks held by caller */
|
|
|
-static void drms_uA_update(struct regulator_dev *rdev)
|
|
|
+static int drms_uA_update(struct regulator_dev *rdev)
|
|
|
{
|
|
|
struct regulator *sibling;
|
|
|
int current_uA = 0, output_uV, input_uV, err;
|
|
|
unsigned int mode;
|
|
|
|
|
|
+ /*
|
|
|
+ * first check to see if we can set modes at all, otherwise just
|
|
|
+ * tell the consumer everything is OK.
|
|
|
+ */
|
|
|
err = regulator_check_drms(rdev);
|
|
|
- if (err < 0 || !rdev->desc->ops->get_optimum_mode ||
|
|
|
- (!rdev->desc->ops->get_voltage &&
|
|
|
- !rdev->desc->ops->get_voltage_sel) ||
|
|
|
- !rdev->desc->ops->set_mode)
|
|
|
- return;
|
|
|
+ if (err < 0)
|
|
|
+ return 0;
|
|
|
+
|
|
|
+ if (!rdev->desc->ops->get_optimum_mode)
|
|
|
+ return 0;
|
|
|
+
|
|
|
+ if (!rdev->desc->ops->set_mode)
|
|
|
+ return -EINVAL;
|
|
|
|
|
|
/* get output voltage */
|
|
|
output_uV = _regulator_get_voltage(rdev);
|
|
|
- if (output_uV <= 0)
|
|
|
- return;
|
|
|
+ if (output_uV <= 0) {
|
|
|
+ rdev_err(rdev, "invalid output voltage found\n");
|
|
|
+ return -EINVAL;
|
|
|
+ }
|
|
|
|
|
|
/* get input voltage */
|
|
|
input_uV = 0;
|
|
@@ -682,8 +691,10 @@ static void drms_uA_update(struct regulator_dev *rdev)
|
|
|
input_uV = regulator_get_voltage(rdev->supply);
|
|
|
if (input_uV <= 0)
|
|
|
input_uV = rdev->constraints->input_uV;
|
|
|
- if (input_uV <= 0)
|
|
|
- return;
|
|
|
+ if (input_uV <= 0) {
|
|
|
+ rdev_err(rdev, "invalid input voltage found\n");
|
|
|
+ return -EINVAL;
|
|
|
+ }
|
|
|
|
|
|
/* calc total requested load */
|
|
|
list_for_each_entry(sibling, &rdev->consumer_list, list)
|
|
@@ -695,8 +706,17 @@ static void drms_uA_update(struct regulator_dev *rdev)
|
|
|
|
|
|
/* check the new mode is allowed */
|
|
|
err = regulator_mode_constrain(rdev, &mode);
|
|
|
- if (err == 0)
|
|
|
- rdev->desc->ops->set_mode(rdev, mode);
|
|
|
+ if (err < 0) {
|
|
|
+ rdev_err(rdev, "failed to get optimum mode @ %d uA %d -> %d uV\n",
|
|
|
+ current_uA, input_uV, output_uV);
|
|
|
+ return err;
|
|
|
+ }
|
|
|
+
|
|
|
+ err = rdev->desc->ops->set_mode(rdev, mode);
|
|
|
+ if (err < 0)
|
|
|
+ rdev_err(rdev, "failed to set optimum mode %x\n", mode);
|
|
|
+
|
|
|
+ return err;
|
|
|
}
|
|
|
|
|
|
static int suspend_set_state(struct regulator_dev *rdev,
|
|
@@ -3024,75 +3044,13 @@ EXPORT_SYMBOL_GPL(regulator_get_mode);
|
|
|
int regulator_set_optimum_mode(struct regulator *regulator, int uA_load)
|
|
|
{
|
|
|
struct regulator_dev *rdev = regulator->rdev;
|
|
|
- struct regulator *consumer;
|
|
|
- int ret, output_uV, input_uV = 0, total_uA_load = 0;
|
|
|
- unsigned int mode;
|
|
|
-
|
|
|
- if (rdev->supply)
|
|
|
- input_uV = regulator_get_voltage(rdev->supply);
|
|
|
+ int ret;
|
|
|
|
|
|
mutex_lock(&rdev->mutex);
|
|
|
-
|
|
|
- /*
|
|
|
- * first check to see if we can set modes at all, otherwise just
|
|
|
- * tell the consumer everything is OK.
|
|
|
- */
|
|
|
regulator->uA_load = uA_load;
|
|
|
- ret = regulator_check_drms(rdev);
|
|
|
- if (ret < 0) {
|
|
|
- ret = 0;
|
|
|
- goto out;
|
|
|
- }
|
|
|
-
|
|
|
- if (!rdev->desc->ops->get_optimum_mode)
|
|
|
- goto out;
|
|
|
-
|
|
|
- /*
|
|
|
- * we can actually do this so any errors are indicators of
|
|
|
- * potential real failure.
|
|
|
- */
|
|
|
- ret = -EINVAL;
|
|
|
-
|
|
|
- if (!rdev->desc->ops->set_mode)
|
|
|
- goto out;
|
|
|
-
|
|
|
- /* get output voltage */
|
|
|
- output_uV = _regulator_get_voltage(rdev);
|
|
|
- if (output_uV <= 0) {
|
|
|
- rdev_err(rdev, "invalid output voltage found\n");
|
|
|
- goto out;
|
|
|
- }
|
|
|
-
|
|
|
- /* No supply? Use constraint voltage */
|
|
|
- if (input_uV <= 0)
|
|
|
- input_uV = rdev->constraints->input_uV;
|
|
|
- if (input_uV <= 0) {
|
|
|
- rdev_err(rdev, "invalid input voltage found\n");
|
|
|
- goto out;
|
|
|
- }
|
|
|
-
|
|
|
- /* calc total requested load for this regulator */
|
|
|
- list_for_each_entry(consumer, &rdev->consumer_list, list)
|
|
|
- total_uA_load += consumer->uA_load;
|
|
|
-
|
|
|
- mode = rdev->desc->ops->get_optimum_mode(rdev,
|
|
|
- input_uV, output_uV,
|
|
|
- total_uA_load);
|
|
|
- ret = regulator_mode_constrain(rdev, &mode);
|
|
|
- if (ret < 0) {
|
|
|
- rdev_err(rdev, "failed to get optimum mode @ %d uA %d -> %d uV\n",
|
|
|
- total_uA_load, input_uV, output_uV);
|
|
|
- goto out;
|
|
|
- }
|
|
|
-
|
|
|
- ret = rdev->desc->ops->set_mode(rdev, mode);
|
|
|
- if (ret < 0) {
|
|
|
- rdev_err(rdev, "failed to set optimum mode %x\n", mode);
|
|
|
- goto out;
|
|
|
- }
|
|
|
- ret = mode;
|
|
|
-out:
|
|
|
+ ret = drms_uA_update(rdev);
|
|
|
mutex_unlock(&rdev->mutex);
|
|
|
+
|
|
|
return ret;
|
|
|
}
|
|
|
EXPORT_SYMBOL_GPL(regulator_set_optimum_mode);
|