@@ -162,6 +162,16 @@ static ssize_t vendor_diag_write(struct file *file, const char __user *user_buf,
|
|
|
if (strtobool(buf, &enable))
|
|
|
return -EINVAL;
|
|
|
|
|
|
+ /* When the diagnostic flags are not persistent and the transport
|
|
|
+ * is not active, then there is no need for the vendor callback.
|
|
|
+ *
|
|
|
+ * Instead just store the desired value. If needed the setting
|
|
|
+ * will be programmed when the controller gets powered on.
|
|
|
+ */
|
|
|
+ if (test_bit(HCI_QUIRK_NON_PERSISTENT_DIAG, &hdev->quirks) &&
|
|
|
+ !test_bit(HCI_RUNNING, &hdev->flags))
|
|
|
+ goto done;
|
|
|
+
|
|
|
hci_req_lock(hdev);
|
|
|
err = hdev->set_diag(hdev, enable);
|
|
|
hci_req_unlock(hdev);
|
|
@@ -169,6 +179,7 @@ static ssize_t vendor_diag_write(struct file *file, const char __user *user_buf,
|
|
|
if (err < 0)
|
|
|
return err;
|
|
|
|
|
|
+done:
|
|
|
if (enable)
|
|
|
hci_dev_set_flag(hdev, HCI_VENDOR_DIAG);
|
|
|
else
|
|
@@ -1494,6 +1505,14 @@ static int hci_dev_do_open(struct hci_dev *hdev)
|
|
|
ret = __hci_init(hdev);
|
|
|
}
|
|
|
|
|
|
+ /* If the HCI Reset command is clearing all diagnostic settings,
|
|
|
+ * then they need to be reprogrammed after the init procedure
|
|
|
+ * completed.
|
|
|
+ */
|
|
|
+ if (test_bit(HCI_QUIRK_NON_PERSISTENT_DIAG, &hdev->quirks) &&
|
|
|
+ hci_dev_test_flag(hdev, HCI_VENDOR_DIAG) && hdev->set_diag)
|
|
|
+ ret = hdev->set_diag(hdev, true);
|
|
|
+
|
|
|
clear_bit(HCI_INIT, &hdev->flags);
|
|
|
|
|
|
if (!ret) {
|