Browse Source

drm/imx: parallel-display: Accept drm_of_find_panel_or_bridge failure

The parallel panel driver should continue to work without having an
endpoint linking to an panel in DT for backwards compatibility.
With the recent switch to drm_of_find_panel_or_bridge, an absent
panel results in a failure with -ENODEV error return code. To restore
the old behaviour, ignore the -ENODEV return code.

Reported-by: Nikita Yushchenko <nikita.yoush@cogentembedded.com>
Fixes: ebc944613567 ("drm: convert drivers to use drm_of_find_panel_or_bridge")
Tested-by: Chris Healy <cphealy@gmail.com>
Cc: stable@vger.kernel.org
Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de>
Philipp Zabel 8 years ago
parent
commit
799ee29704
1 changed files with 1 additions and 1 deletions
  1. 1 1
      drivers/gpu/drm/imx/parallel-display.c

+ 1 - 1
drivers/gpu/drm/imx/parallel-display.c

@@ -237,7 +237,7 @@ static int imx_pd_bind(struct device *dev, struct device *master, void *data)
 
 	/* port@1 is the output port */
 	ret = drm_of_find_panel_or_bridge(np, 1, 0, &imxpd->panel, &imxpd->bridge);
-	if (ret)
+	if (ret && ret != -ENODEV)
 		return ret;
 
 	imxpd->dev = dev;