Explorar el Código

Input: ads7846 - allow specifying irq trigger type in platform data

On some platforms, for example with GPIO interrupts on mpc5121,
it is not possible to configure falling edge interrupts.

Specifying irq trigger type in platform data structure
allows using ads7846 driver on such platforms.

Signed-off-by: Anatolij Gustschin <agust@denx.de>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
Anatolij Gustschin hace 15 años
padre
commit
7804302b14
Se han modificado 2 ficheros con 5 adiciones y 1 borrados
  1. 4 1
      drivers/input/touchscreen/ads7846.c
  2. 1 0
      include/linux/spi/ads7846.h

+ 4 - 1
drivers/input/touchscreen/ads7846.c

@@ -1174,7 +1174,10 @@ static int __devinit ads7846_probe(struct spi_device *spi)
 		goto err_put_regulator;
 	}
 
-	if (request_irq(spi->irq, ads7846_irq, IRQF_TRIGGER_FALLING,
+	if (!pdata->irq_flags)
+		pdata->irq_flags = IRQF_TRIGGER_FALLING;
+
+	if (request_irq(spi->irq, ads7846_irq, pdata->irq_flags,
 			spi->dev.driver->name, ts)) {
 		dev_info(&spi->dev,
 			"trying pin change workaround on irq %d\n", spi->irq);

+ 1 - 0
include/linux/spi/ads7846.h

@@ -54,5 +54,6 @@ struct ads7846_platform_data {
 	void	(*filter_cleanup)(void *filter_data);
 	void	(*wait_for_sync)(void);
 	bool	wakeup;
+	unsigned long irq_flags;
 };