@@ -151,9 +151,9 @@ TRACE_EVENT(thermal_power_cpu_limit,
|
|
|
TRACE_EVENT(thermal_power_devfreq_get_power,
|
|
|
TP_PROTO(struct thermal_cooling_device *cdev,
|
|
|
struct devfreq_dev_status *status, unsigned long freq,
|
|
|
- u32 dynamic_power, u32 static_power),
|
|
|
+ u32 dynamic_power, u32 static_power, u32 power),
|
|
|
|
|
|
- TP_ARGS(cdev, status, freq, dynamic_power, static_power),
|
|
|
+ TP_ARGS(cdev, status, freq, dynamic_power, static_power, power),
|
|
|
|
|
|
TP_STRUCT__entry(
|
|
|
__string(type, cdev->type )
|
|
@@ -161,6 +161,7 @@ TRACE_EVENT(thermal_power_devfreq_get_power,
|
|
|
__field(u32, load )
|
|
|
__field(u32, dynamic_power )
|
|
|
__field(u32, static_power )
|
|
|
+ __field(u32, power)
|
|
|
),
|
|
|
|
|
|
TP_fast_assign(
|
|
@@ -169,11 +170,13 @@ TRACE_EVENT(thermal_power_devfreq_get_power,
|
|
|
__entry->load = (100 * status->busy_time) / status->total_time;
|
|
|
__entry->dynamic_power = dynamic_power;
|
|
|
__entry->static_power = static_power;
|
|
|
+ __entry->power = power;
|
|
|
),
|
|
|
|
|
|
- TP_printk("type=%s freq=%lu load=%u dynamic_power=%u static_power=%u",
|
|
|
+ TP_printk("type=%s freq=%lu load=%u dynamic_power=%u static_power=%u power=%u",
|
|
|
__get_str(type), __entry->freq,
|
|
|
- __entry->load, __entry->dynamic_power, __entry->static_power)
|
|
|
+ __entry->load, __entry->dynamic_power, __entry->static_power,
|
|
|
+ __entry->power)
|
|
|
);
|
|
|
|
|
|
TRACE_EVENT(thermal_power_devfreq_limit,
|