@@ -2286,10 +2286,8 @@ static bool sdhci_request_done(struct sdhci_host *host)
|
|
|
|
|
|
for (i = 0; i < SDHCI_MAX_MRQS; i++) {
|
|
|
mrq = host->mrqs_done[i];
|
|
|
- if (mrq) {
|
|
|
- host->mrqs_done[i] = NULL;
|
|
|
+ if (mrq)
|
|
|
break;
|
|
|
- }
|
|
|
}
|
|
|
|
|
|
if (!mrq) {
|
|
@@ -2320,6 +2318,17 @@ static bool sdhci_request_done(struct sdhci_host *host)
|
|
|
* upon error conditions.
|
|
|
*/
|
|
|
if (sdhci_needs_reset(host, mrq)) {
|
|
|
+ /*
|
|
|
+ * Do not finish until command and data lines are available for
|
|
|
+ * reset. Note there can only be one other mrq, so it cannot
|
|
|
+ * also be in mrqs_done, otherwise host->cmd and host->data_cmd
|
|
|
+ * would both be null.
|
|
|
+ */
|
|
|
+ if (host->cmd || host->data_cmd) {
|
|
|
+ spin_unlock_irqrestore(&host->lock, flags);
|
|
|
+ return true;
|
|
|
+ }
|
|
|
+
|
|
|
/* Some controllers need this kick or reset won't work here */
|
|
|
if (host->quirks & SDHCI_QUIRK_CLOCK_BEFORE_RESET)
|
|
|
/* This is to force an update */
|
|
@@ -2327,10 +2336,8 @@ static bool sdhci_request_done(struct sdhci_host *host)
|
|
|
|
|
|
/* Spec says we should do both at the same time, but Ricoh
|
|
|
controllers do not like that. */
|
|
|
- if (!host->cmd)
|
|
|
- sdhci_do_reset(host, SDHCI_RESET_CMD);
|
|
|
- if (!host->data_cmd)
|
|
|
- sdhci_do_reset(host, SDHCI_RESET_DATA);
|
|
|
+ sdhci_do_reset(host, SDHCI_RESET_CMD);
|
|
|
+ sdhci_do_reset(host, SDHCI_RESET_DATA);
|
|
|
|
|
|
host->pending_reset = false;
|
|
|
}
|
|
@@ -2338,6 +2345,8 @@ static bool sdhci_request_done(struct sdhci_host *host)
|
|
|
if (!sdhci_has_requests(host))
|
|
|
sdhci_led_deactivate(host);
|
|
|
|
|
|
+ host->mrqs_done[i] = NULL;
|
|
|
+
|
|
|
mmiowb();
|
|
|
spin_unlock_irqrestore(&host->lock, flags);
|
|
|
|