@@ -45,7 +45,6 @@ static unsigned int debug_quirks2;
|
|
|
|
|
|
static void sdhci_finish_data(struct sdhci_host *);
|
|
|
|
|
|
-static void sdhci_finish_command(struct sdhci_host *);
|
|
|
static void sdhci_enable_preset_value(struct sdhci_host *host, bool enable);
|
|
|
|
|
|
static void sdhci_dumpregs(struct sdhci_host *host)
|
|
@@ -1079,6 +1078,28 @@ static void sdhci_finish_command(struct sdhci_host *host)
|
|
|
}
|
|
|
}
|
|
|
|
|
|
+ /*
|
|
|
+ * The host can send and interrupt when the busy state has
|
|
|
+ * ended, allowing us to wait without wasting CPU cycles.
|
|
|
+ * The busy signal uses DAT0 so this is similar to waiting
|
|
|
+ * for data to complete.
|
|
|
+ *
|
|
|
+ * Note: The 1.0 specification is a bit ambiguous about this
|
|
|
+ * feature so there might be some problems with older
|
|
|
+ * controllers.
|
|
|
+ */
|
|
|
+ if (host->cmd->flags & MMC_RSP_BUSY) {
|
|
|
+ if (host->cmd->data) {
|
|
|
+ DBG("Cannot wait for busy signal when also doing a data transfer");
|
|
|
+ } else if (!(host->quirks & SDHCI_QUIRK_NO_BUSY_IRQ) &&
|
|
|
+ !host->busy_handle) {
|
|
|
+ /* Mark that command complete before busy is ended */
|
|
|
+ host->busy_handle = 1;
|
|
|
+ host->cmd = NULL;
|
|
|
+ return;
|
|
|
+ }
|
|
|
+ }
|
|
|
+
|
|
|
/* Finished CMD23, now send actual command. */
|
|
|
if (host->cmd == host->mrq->sbc) {
|
|
|
host->cmd = NULL;
|
|
@@ -2295,33 +2316,10 @@ static void sdhci_cmd_irq(struct sdhci_host *host, u32 intmask, u32 *mask)
|
|
|
return;
|
|
|
}
|
|
|
|
|
|
- /*
|
|
|
- * The host can send and interrupt when the busy state has
|
|
|
- * ended, allowing us to wait without wasting CPU cycles.
|
|
|
- * Unfortunately this is overloaded on the "data complete"
|
|
|
- * interrupt, so we need to take some care when handling
|
|
|
- * it.
|
|
|
- *
|
|
|
- * Note: The 1.0 specification is a bit ambiguous about this
|
|
|
- * feature so there might be some problems with older
|
|
|
- * controllers.
|
|
|
- */
|
|
|
- if (host->cmd->flags & MMC_RSP_BUSY) {
|
|
|
- if (host->cmd->data)
|
|
|
- DBG("Cannot wait for busy signal when also doing a data transfer");
|
|
|
- else if (!(host->quirks & SDHCI_QUIRK_NO_BUSY_IRQ)
|
|
|
- && !host->busy_handle) {
|
|
|
- /* Mark that command complete before busy is ended */
|
|
|
- host->busy_handle = 1;
|
|
|
- return;
|
|
|
- }
|
|
|
-
|
|
|
- /* The controller does not support the end-of-busy IRQ,
|
|
|
- * fall through and take the SDHCI_INT_RESPONSE */
|
|
|
- } else if ((host->quirks2 & SDHCI_QUIRK2_STOP_WITH_TC) &&
|
|
|
- host->cmd->opcode == MMC_STOP_TRANSMISSION && !host->data) {
|
|
|
+ if ((host->quirks2 & SDHCI_QUIRK2_STOP_WITH_TC) &&
|
|
|
+ !(host->cmd->flags & MMC_RSP_BUSY) && !host->data &&
|
|
|
+ host->cmd->opcode == MMC_STOP_TRANSMISSION)
|
|
|
*mask &= ~SDHCI_INT_DATA_END;
|
|
|
- }
|
|
|
|
|
|
if (intmask & SDHCI_INT_RESPONSE)
|
|
|
sdhci_finish_command(host);
|
|
@@ -2395,7 +2393,7 @@ static void sdhci_data_irq(struct sdhci_host *host, u32 intmask)
|
|
|
* sure we do things in the proper order.
|
|
|
*/
|
|
|
if (host->busy_handle)
|
|
|
- sdhci_finish_command(host);
|
|
|
+ tasklet_schedule(&host->finish_tasklet);
|
|
|
else
|
|
|
host->busy_handle = 1;
|
|
|
return;
|