Browse Source

e1000e: i219 - increase IPG for speed 10/100 full duplex

In SPT/i219, there were CRC errors in speed 10/100 full duplex.
The solution given by the HW team is to increase the IPG from 8 to 0xC

Signed-off-by: Yanir Lubetkin <yanirx.lubetkin@intel.com>
Tested-by: Aaron Brown <aaron.f.brown@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Yanir Lubetkin 10 years ago
parent
commit
69cfbc95bd
1 changed files with 7 additions and 3 deletions
  1. 7 3
      drivers/net/ethernet/intel/e1000e/ich8lan.c

+ 7 - 3
drivers/net/ethernet/intel/e1000e/ich8lan.c

@@ -1400,16 +1400,20 @@ static s32 e1000_check_for_copper_link_ich8lan(struct e1000_hw *hw)
 	if (((hw->mac.type == e1000_pch2lan) ||
 	     (hw->mac.type == e1000_pch_lpt) ||
 	     (hw->mac.type == e1000_pch_spt)) && link) {
-		u32 reg;
+		u16 speed, duplex;
 
-		reg = er32(STATUS);
+		e1000e_get_speed_and_duplex_copper(hw, &speed, &duplex);
 		tipg_reg = er32(TIPG);
 		tipg_reg &= ~E1000_TIPG_IPGT_MASK;
 
-		if (!(reg & (E1000_STATUS_FD | E1000_STATUS_SPEED_MASK))) {
+		if (duplex == HALF_DUPLEX && speed == SPEED_10) {
 			tipg_reg |= 0xFF;
 			/* Reduce Rx latency in analog PHY */
 			emi_val = 0;
+		} else if (hw->mac.type == e1000_pch_spt &&
+			   duplex == FULL_DUPLEX && speed != SPEED_1000) {
+			tipg_reg |= 0xC;
+			emi_val = 1;
 		} else {
 
 			/* Roll back the default values */