瀏覽代碼

net:phy:dp83640: Move all HW initialization to dp83640_config_init

phy_init_hw not does a full PHY reset after the driver probe has
finished, so any hw initialization done in the probe will be lost.
Part of the timestamping functionality of the dp83640 is set up in the
probe and with that lost, enabling timestamping will cause a PHY
lockup, requiring a hard reset / power cycle to recover.

This patch moves all the HW initialization in dp83640_probe to
dp83640_config_init.

Signed-off-by: Stefan Sørensen <stefan.sorensen@spectralink.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Stefan Sørensen 11 年之前
父節點
當前提交
602b109942
共有 1 個文件被更改,包括 8 次插入5 次删除
  1. 8 5
      drivers/net/phy/dp83640.c

+ 8 - 5
drivers/net/phy/dp83640.c

@@ -1006,11 +1006,6 @@ static int dp83640_probe(struct phy_device *phydev)
 	} else
 		list_add_tail(&dp83640->list, &clock->phylist);
 
-	if (clock->chosen && !list_empty(&clock->phylist))
-		recalibrate(clock);
-	else
-		enable_broadcast(dp83640->phydev, clock->page, 1);
-
 	dp83640_clock_put(clock);
 	return 0;
 
@@ -1063,6 +1058,14 @@ static void dp83640_remove(struct phy_device *phydev)
 
 static int dp83640_config_init(struct phy_device *phydev)
 {
+	struct dp83640_private *dp83640 = phydev->priv;
+	struct dp83640_clock *clock = dp83640->clock;
+
+	if (clock->chosen && !list_empty(&clock->phylist))
+		recalibrate(clock);
+	else
+		enable_broadcast(phydev, clock->page, 1);
+
 	enable_status_frames(phydev, true);
 	ext_write(0, phydev, PAGE4, PTP_CTL, PTP_ENABLE);
 	return 0;