@@ -289,7 +289,8 @@ accepts values 0-511 and the driver reports 0-65535, step should be
|
|
|
<entry>The default value of a
|
|
|
<constant>V4L2_CTRL_TYPE_INTEGER</constant>, <constant>_INTEGER64</constant>,
|
|
|
<constant>_BOOLEAN</constant>, <constant>_BITMASK</constant>,
|
|
|
-<constant>_MENU</constant> or <constant>_INTEGER_MENU</constant> control.
|
|
|
+<constant>_MENU</constant>, <constant>_INTEGER_MENU</constant>,
|
|
|
+<constant>_U8</constant> or <constant>_U16</constant> control.
|
|
|
Not valid for other types of controls.
|
|
|
Note that drivers reset controls to their default value only when the
|
|
|
driver is first loaded, never afterwards.
|
|
@@ -510,6 +511,26 @@ ioctl returns the name of the control class and this control type.
|
|
|
Older drivers which do not support this feature return an
|
|
|
&EINVAL;.</entry>
|
|
|
</row>
|
|
|
+ <row>
|
|
|
+ <entry><constant>V4L2_CTRL_TYPE_U8</constant></entry>
|
|
|
+ <entry>any</entry>
|
|
|
+ <entry>any</entry>
|
|
|
+ <entry>any</entry>
|
|
|
+ <entry>An unsigned 8-bit valued control ranging from minimum to
|
|
|
+maximum inclusive. The step value indicates the increment between
|
|
|
+values which are actually different on the hardware. This type is only used
|
|
|
+in array controls.</entry>
|
|
|
+ </row>
|
|
|
+ <row>
|
|
|
+ <entry><constant>V4L2_CTRL_TYPE_U16</constant></entry>
|
|
|
+ <entry>any</entry>
|
|
|
+ <entry>any</entry>
|
|
|
+ <entry>any</entry>
|
|
|
+ <entry>An unsigned 16-bit valued control ranging from minimum to
|
|
|
+maximum inclusive. The step value indicates the increment between
|
|
|
+values which are actually different on the hardware. This type is only used
|
|
|
+in array controls.</entry>
|
|
|
+ </row>
|
|
|
</tbody>
|
|
|
</tgroup>
|
|
|
</table>
|