@@ -86,8 +86,14 @@ Optional properties:
|
|
Single entry is for target voltage and three entries are for <target min max>
|
|
Single entry is for target voltage and three entries are for <target min max>
|
|
voltages.
|
|
voltages.
|
|
|
|
|
|
- Entries for multiple regulators must be present in the same order as
|
|
|
|
- regulators are specified in device's DT node.
|
|
|
|
|
|
+ Entries for multiple regulators shall be provided in the same field separated
|
|
|
|
+ by angular brackets <>. The OPP binding doesn't provide any provisions to
|
|
|
|
+ relate the values to their power supplies or the order in which the supplies
|
|
|
|
+ need to be configured and that is left for the implementation specific
|
|
|
|
+ binding.
|
|
|
|
+
|
|
|
|
+ Entries for all regulators shall be of the same size, i.e. either all use a
|
|
|
|
+ single value or triplets.
|
|
|
|
|
|
- opp-microvolt-<name>: Named opp-microvolt property. This is exactly similar to
|
|
- opp-microvolt-<name>: Named opp-microvolt property. This is exactly similar to
|
|
the above opp-microvolt property, but allows multiple voltage ranges to be
|
|
the above opp-microvolt property, but allows multiple voltage ranges to be
|
|
@@ -104,10 +110,13 @@ Optional properties:
|
|
|
|
|
|
Should only be set if opp-microvolt is set for the OPP.
|
|
Should only be set if opp-microvolt is set for the OPP.
|
|
|
|
|
|
- Entries for multiple regulators must be present in the same order as
|
|
|
|
- regulators are specified in device's DT node. If this property isn't required
|
|
|
|
- for few regulators, then this should be marked as zero for them. If it isn't
|
|
|
|
- required for any regulator, then this property need not be present.
|
|
|
|
|
|
+ Entries for multiple regulators shall be provided in the same field separated
|
|
|
|
+ by angular brackets <>. If current values aren't required for a regulator,
|
|
|
|
+ then it shall be filled with 0. If current values aren't required for any of
|
|
|
|
+ the regulators, then this field is not required. The OPP binding doesn't
|
|
|
|
+ provide any provisions to relate the values to their power supplies or the
|
|
|
|
+ order in which the supplies need to be configured and that is left for the
|
|
|
|
+ implementation specific binding.
|
|
|
|
|
|
- opp-microamp-<name>: Named opp-microamp property. Similar to
|
|
- opp-microamp-<name>: Named opp-microamp property. Similar to
|
|
opp-microvolt-<name> property, but for microamp instead.
|
|
opp-microvolt-<name> property, but for microamp instead.
|