Эх сурвалжийг харах

batman-adv: Avoid u32 overflow during gateway select

The gateway selection based on fast connections is using a single value
calculated from the average tq (0-255) and the download bandwidth (in
100Kibit). The formula for the first step (tq ** 2 * 10000 * bandwidth)
tends to overflow a u32 with low bandwidth settings like 50 [100KiBit]
and a tq value of over 92.

Changing this to a 64 bit unsigned integer allows to support a
bandwidth_down with up to ~2.8e10 [100KiBit] and a perfect tq of 255. This
is ~6.6 times higher than the maximum possible value of the gateway
announcement TVLV.

This problem only affects the non-default gw_sel_class 1.

Signed-off-by: Ruben Wisniewsi <ruben@vfn-nrw.de>
[sven@narfation.org: rewritten commit message]
Signed-off-by: Sven Eckelmann <sven@narfation.org>
Signed-off-by: Marek Lindner <mareklindner@neomailbox.ch>
Signed-off-by: Antonio Quartulli <antonio@meshcoding.com>
Ruben Wisniewski 10 жил өмнө
parent
commit
571a963768

+ 1 - 1
net/batman-adv/gateway_client.c

@@ -153,7 +153,7 @@ batadv_gw_get_best_gw_node(struct batadv_priv *bat_priv)
 	struct batadv_neigh_node *router;
 	struct batadv_neigh_ifinfo *router_ifinfo;
 	struct batadv_gw_node *gw_node, *curr_gw = NULL;
-	uint32_t max_gw_factor = 0, tmp_gw_factor = 0;
+	uint64_t max_gw_factor = 0, tmp_gw_factor = 0;
 	uint8_t max_tq = 0;
 	uint8_t tq_avg;
 	struct batadv_orig_node *orig_node;