瀏覽代碼

tty: acpi/spcr: QDF2400 E44 checks for wrong OEM revision

For Qualcomm Technologies QDF2400 SOCs that are affected by erratum E44,
the ACPI oem_revision field is actually set to 1, not 0.

Fixes: d8a4995bcea1 ("tty: pl011: Work around QDF2400 E44 stuck BUSY bit")

Tested-by: Manoj Iyer <manoj.iyer@canonical.com>
Signed-off-by: Timur Tabi <timur@codeaurora.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Timur Tabi 8 年之前
父節點
當前提交
542ed78467
共有 1 個文件被更改,包括 1 次插入1 次删除
  1. 1 1
      drivers/acpi/spcr.c

+ 1 - 1
drivers/acpi/spcr.c

@@ -30,7 +30,7 @@ static bool qdf2400_erratum_44_present(struct acpi_table_header *h)
 		return true;
 		return true;
 
 
 	if (!memcmp(h->oem_table_id, "QDF2400 ", ACPI_OEM_TABLE_ID_SIZE) &&
 	if (!memcmp(h->oem_table_id, "QDF2400 ", ACPI_OEM_TABLE_ID_SIZE) &&
-			h->oem_revision == 0)
+			h->oem_revision == 1)
 		return true;
 		return true;
 
 
 	return false;
 	return false;