@@ -534,20 +534,6 @@ static int acpi_battery_get_state(struct acpi_battery *battery)
|
|
|
" invalid.\n");
|
|
|
}
|
|
|
|
|
|
- /*
|
|
|
- * When fully charged, some batteries wrongly report
|
|
|
- * capacity_now = design_capacity instead of = full_charge_capacity
|
|
|
- */
|
|
|
- if (battery->capacity_now > battery->full_charge_capacity
|
|
|
- && battery->full_charge_capacity != ACPI_BATTERY_VALUE_UNKNOWN) {
|
|
|
- battery->capacity_now = battery->full_charge_capacity;
|
|
|
- if (battery->capacity_now != battery->design_capacity)
|
|
|
- printk_once(KERN_WARNING FW_BUG
|
|
|
- "battery: reported current charge level (%d) "
|
|
|
- "is higher than reported maximum charge level (%d).\n",
|
|
|
- battery->capacity_now, battery->full_charge_capacity);
|
|
|
- }
|
|
|
-
|
|
|
if (test_bit(ACPI_BATTERY_QUIRK_PERCENTAGE_CAPACITY, &battery->flags)
|
|
|
&& battery->capacity_now >= 0 && battery->capacity_now <= 100)
|
|
|
battery->capacity_now = (battery->capacity_now *
|