@@ -0,0 +1,23 @@
|
|
|
+Dialog Semiconductor DA9150 Fuel-Gauge Power Supply bindings
|
|
|
+
|
|
|
+Required properties:
|
|
|
+- compatible: "dlg,da9150-fuel-gauge" for DA9150 Fuel-Gauge Power Supply
|
|
|
+
|
|
|
+Optional properties:
|
|
|
+- dlg,update-interval: Interval time (milliseconds) between battery level checks.
|
|
|
+- dlg,warn-soc-level: Battery discharge level (%) where warning event raised.
|
|
|
+ [1 - 100]
|
|
|
+- dlg,crit-soc-level: Battery discharge level (%) where critical event raised.
|
|
|
+ This value should be lower than the warning level.
|
|
|
+ [1 - 100]
|
|
|
+
|
|
|
+
|
|
|
+Example:
|
|
|
+
|
|
|
+ fuel-gauge {
|
|
|
+ compatible = "dlg,da9150-fuel-gauge";
|
|
|
+
|
|
|
+ dlg,update-interval = <10000>;
|
|
|
+ dlg,warn-soc-level = /bits/ 8 <15>;
|
|
|
+ dlg,crit-soc-level = /bits/ 8 <5>;
|
|
|
+ };
|