@@ -166,7 +166,6 @@ struct usbduxsigma_private {
|
|
|
|
|
|
/* number of samples to acquire */
|
|
/* number of samples to acquire */
|
|
int ai_sample_count;
|
|
int ai_sample_count;
|
|
- int ao_sample_count;
|
|
|
|
/* time between samples in units of the timer */
|
|
/* time between samples in units of the timer */
|
|
unsigned int ai_timer;
|
|
unsigned int ai_timer;
|
|
unsigned int ao_timer;
|
|
unsigned int ao_timer;
|
|
@@ -358,12 +357,10 @@ static void usbduxsigma_ao_handle_urb(struct comedi_device *dev,
|
|
if (devpriv->ao_counter == 0) {
|
|
if (devpriv->ao_counter == 0) {
|
|
devpriv->ao_counter = devpriv->ao_timer;
|
|
devpriv->ao_counter = devpriv->ao_timer;
|
|
|
|
|
|
- if (cmd->stop_src == TRIG_COUNT) {
|
|
|
|
- devpriv->ao_sample_count--;
|
|
|
|
- if (devpriv->ao_sample_count < 0) {
|
|
|
|
- async->events |= COMEDI_CB_EOA;
|
|
|
|
- return;
|
|
|
|
- }
|
|
|
|
|
|
+ if (cmd->stop_src == TRIG_COUNT &&
|
|
|
|
+ async->scans_done >= cmd->stop_arg) {
|
|
|
|
+ async->events |= COMEDI_CB_EOA;
|
|
|
|
+ return;
|
|
}
|
|
}
|
|
|
|
|
|
/* transmit data to the USB bus */
|
|
/* transmit data to the USB bus */
|
|
@@ -952,25 +949,6 @@ static int usbduxsigma_ao_cmdtest(struct comedi_device *dev,
|
|
if (devpriv->ao_timer < 1)
|
|
if (devpriv->ao_timer < 1)
|
|
err |= -EINVAL;
|
|
err |= -EINVAL;
|
|
|
|
|
|
- if (cmd->stop_src == TRIG_COUNT) {
|
|
|
|
- /* not continuous, use counter */
|
|
|
|
- if (high_speed) {
|
|
|
|
- /* high speed also scans everything at once */
|
|
|
|
- devpriv->ao_sample_count = cmd->stop_arg *
|
|
|
|
- cmd->scan_end_arg;
|
|
|
|
- } else {
|
|
|
|
- /*
|
|
|
|
- * There's no scan as the scan has been
|
|
|
|
- * handled inside the FX2. Data arrives as
|
|
|
|
- * one packet.
|
|
|
|
- */
|
|
|
|
- devpriv->ao_sample_count = cmd->stop_arg;
|
|
|
|
- }
|
|
|
|
- } else {
|
|
|
|
- /* continuous acquisition */
|
|
|
|
- devpriv->ao_sample_count = 0;
|
|
|
|
- }
|
|
|
|
-
|
|
|
|
if (err)
|
|
if (err)
|
|
return 4;
|
|
return 4;
|
|
|
|
|