Browse Source

raid10: change the size of resync window for clustered raid

To align with raid1's resync window, we need to
set the resync window of raid10 to 32M as well.

Fixes: 8db87912c9a8 ("md-cluster: Use a small window for raid10 resync")
Reported-by: Zhilong Liu <zlliu@suse.com>
Signed-off-by: Guoqing Jiang <gqjiang@suse.com>
Signed-off-by: Shaohua Li <sh.li@alibaba-inc.com>
Guoqing Jiang 7 years ago
parent
commit
4b242e97d7
1 changed files with 1 additions and 1 deletions
  1. 1 1
      drivers/md/raid10.c

+ 1 - 1
drivers/md/raid10.c

@@ -141,7 +141,7 @@ static void r10bio_pool_free(void *r10_bio, void *data)
 #define RESYNC_WINDOW (1024*1024)
 /* maximum number of concurrent requests, memory permitting */
 #define RESYNC_DEPTH (32*1024*1024/RESYNC_BLOCK_SIZE)
-#define CLUSTER_RESYNC_WINDOW (16 * RESYNC_WINDOW)
+#define CLUSTER_RESYNC_WINDOW (32 * RESYNC_WINDOW)
 #define CLUSTER_RESYNC_WINDOW_SECTORS (CLUSTER_RESYNC_WINDOW >> 9)
 
 /*