瀏覽代碼

staging:iio:documentation pull a few sysfs entries out of main docs.

These two attributes are only used in the one driver.  Whilst they
are fairly general I'm not entirely happy committing to them at
this stage.

Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Jonathan Cameron 13 年之前
父節點
當前提交
49c36dffbd
共有 2 個文件被更改,包括 20 次插入21 次删除
  1. 0 21
      drivers/staging/iio/Documentation/sysfs-bus-iio
  2. 20 0
      drivers/staging/iio/Documentation/sysfs-bus-iio-ad7192

+ 0 - 21
drivers/staging/iio/Documentation/sysfs-bus-iio

@@ -728,24 +728,3 @@ Contact:	linux-iio@vger.kernel.org
 Description:
 Description:
 		This attribute is used to read the amount of quadrature error
 		This attribute is used to read the amount of quadrature error
 		present in the device at a given time.
 		present in the device at a given time.
-
-What:		/sys/.../iio:deviceX/ac_excitation_en
-KernelVersion:	3.1.0
-Contact:	linux-iio@vger.kernel.org
-Description:
-		This attribute, if available, is used to enable the AC
-		excitation mode found on some converters. In ac excitation mode,
-		the polarity of the excitation voltage is reversed on
-		alternate cycles, to eliminate DC errors.
-
-What:		/sys/.../iio:deviceX/bridge_switch_en
-KernelVersion:	3.1.0
-Contact:	linux-iio@vger.kernel.org
-Description:
-		This attribute, if available, is used to close or open the
-		bridge power down switch found on some converters.
-		In bridge applications, such as strain gauges and load cells,
-		the bridge itself consumes the majority of the current in the
-		system. To minimize the current consumption of the system,
-		the bridge can be disconnected (when it is not being used
-		using the bridge_switch_en attribute.

+ 20 - 0
drivers/staging/iio/Documentation/sysfs-bus-iio-ad7192

@@ -0,0 +1,20 @@
+What:		/sys/.../iio:deviceX/ac_excitation_en
+KernelVersion:	3.1.0
+Contact:	linux-iio@vger.kernel.org
+Description:
+		This attribute, if available, is used to enable the AC
+		excitation mode found on some converters. In ac excitation mode,
+		the polarity of the excitation voltage is reversed on
+		alternate cycles, to eliminate DC errors.
+
+What:		/sys/.../iio:deviceX/bridge_switch_en
+KernelVersion:	3.1.0
+Contact:	linux-iio@vger.kernel.org
+Description:
+		This attribute, if available, is used to close or open the
+		bridge power down switch found on some converters.
+		In bridge applications, such as strain gauges and load cells,
+		the bridge itself consumes the majority of the current in the
+		system. To minimize the current consumption of the system,
+		the bridge can be disconnected (when it is not being used
+		using the bridge_switch_en attribute.