powerpc/powernv: Display the correct error info for CAPP errors.

On some CAPP errors we see console messages that prints unknown HMIs for
which CAPI recovery is in progress. This patch fixes this by printing
correct error info for HMI generated due to CAPP recovery.

Signed-off-by: Mahesh Salgaonkar <mahesh@linux.vnet.ibm.com>
Tested-by: Andrew Donnellan <andrew.donnellan@au1.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Mahesh Salgaonkar 8 năm trước cách đây
mục cha
commit
470a36a8c0
1 tập tin đã thay đổi với 2 bổ sung1 xóa
  1. 2 1
      arch/powerpc/platforms/powernv/opal-hmi.c

+ 2 - 1
arch/powerpc/platforms/powernv/opal-hmi.c

@@ -180,7 +180,8 @@ static void print_hmi_event_info(struct OpalHMIEvent *hmi_evt)
 		"An XSCOM operation completed",
 		"SCOM has set a reserved FIR bit to cause recovery",
 		"Debug trigger has set a reserved FIR bit to cause recovery",
-		"A hypervisor resource error occurred"
+		"A hypervisor resource error occurred",
+		"CAPP recovery process is in progress",
 	};
 