Преглед изворни кода

powerpc/powernv: Display the correct error info for CAPP errors.

On some CAPP errors we see console messages that prints unknown HMIs for
which CAPI recovery is in progress. This patch fixes this by printing
correct error info for HMI generated due to CAPP recovery.

Signed-off-by: Mahesh Salgaonkar <mahesh@linux.vnet.ibm.com>
Tested-by: Andrew Donnellan <andrew.donnellan@au1.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
Mahesh Salgaonkar пре 8 година
родитељ
комит
470a36a8c0
1 измењених фајлова са 2 додато и 1 уклоњено
  1. 2 1
      arch/powerpc/platforms/powernv/opal-hmi.c

+ 2 - 1
arch/powerpc/platforms/powernv/opal-hmi.c

@@ -180,7 +180,8 @@ static void print_hmi_event_info(struct OpalHMIEvent *hmi_evt)
 		"An XSCOM operation completed",
 		"SCOM has set a reserved FIR bit to cause recovery",
 		"Debug trigger has set a reserved FIR bit to cause recovery",
-		"A hypervisor resource error occurred"
+		"A hypervisor resource error occurred",
+		"CAPP recovery process is in progress",
 	};
 
 	/* Print things out */