@@ -201,8 +201,31 @@ static unsigned int dw8250_serial_in32be(struct uart_port *p, int offset)
|
|
|
|
|
|
static int dw8250_handle_irq(struct uart_port *p)
|
|
|
{
|
|
|
+ struct uart_8250_port *up = up_to_u8250p(p);
|
|
|
struct dw8250_data *d = p->private_data;
|
|
|
unsigned int iir = p->serial_in(p, UART_IIR);
|
|
|
+ unsigned int status;
|
|
|
+ unsigned long flags;
|
|
|
+
|
|
|
+ /*
|
|
|
+ * There are ways to get Designware-based UARTs into a state where
|
|
|
+ * they are asserting UART_IIR_RX_TIMEOUT but there is no actual
|
|
|
+ * data available. If we see such a case then we'll do a bogus
|
|
|
+ * read. If we don't do this then the "RX TIMEOUT" interrupt will
|
|
|
+ * fire forever.
|
|
|
+ *
|
|
|
+ * This problem has only been observed so far when not in DMA mode
|
|
|
+ * so we limit the workaround only to non-DMA mode.
|
|
|
+ */
|
|
|
+ if (!up->dma && ((iir & 0x3f) == UART_IIR_RX_TIMEOUT)) {
|
|
|
+ spin_lock_irqsave(&p->lock, flags);
|
|
|
+ status = p->serial_in(p, UART_LSR);
|
|
|
+
|
|
|
+ if (!(status & (UART_LSR_DR | UART_LSR_BI)))
|
|
|
+ (void) p->serial_in(p, UART_RX);
|
|
|
+
|
|
|
+ spin_unlock_irqrestore(&p->lock, flags);
|
|
|
+ }
|
|
|
|
|
|
if (serial8250_handle_irq(p, iir))
|
|
|
return 1;
|