@@ -3,10 +3,35 @@ Bindings for a fan connected to the PWM lines
|
|
|
Required properties:
|
|
|
- compatible : "pwm-fan"
|
|
|
- pwms : the PWM that is used to control the PWM fan
|
|
|
+- cooling-levels : PWM duty cycle values in a range from 0 to 255
|
|
|
+ which correspond to thermal cooling states
|
|
|
|
|
|
Example:
|
|
|
- pwm-fan {
|
|
|
+ fan0: pwm-fan {
|
|
|
compatible = "pwm-fan";
|
|
|
- status = "okay";
|
|
|
+ cooling-min-state = <0>;
|
|
|
+ cooling-max-state = <3>;
|
|
|
+ #cooling-cells = <2>;
|
|
|
pwms = <&pwm 0 10000 0>;
|
|
|
+ cooling-levels = <0 102 170 230>;
|
|
|
};
|
|
|
+
|
|
|
+ thermal-zones {
|
|
|
+ cpu_thermal: cpu-thermal {
|
|
|
+ thermal-sensors = <&tmu 0>;
|
|
|
+ polling-delay-passive = <0>;
|
|
|
+ polling-delay = <0>;
|
|
|
+ trips {
|
|
|
+ cpu_alert1: cpu-alert1 {
|
|
|
+ temperature = <100000>; /* millicelsius */
|
|
|
+ hysteresis = <2000>; /* millicelsius */
|
|
|
+ type = "passive";
|
|
|
+ };
|
|
|
+ };
|
|
|
+ cooling-maps {
|
|
|
+ map0 {
|
|
|
+ trip = <&cpu_alert1>;
|
|
|
+ cooling-device = <&fan0 0 1>;
|
|
|
+ };
|
|
|
+ };
|
|
|
+ };
|