md/raid5: Mark device want_replacement when we see a write error.

Now that WantReplacement drives are replaced cleanly, mark a drive
as WantReplacement when we see a write error.  It might get failed soon so
the WantReplacement flag is irrelevant, but if the write error is recorded
in the bad block log, we still want to activate any spare that might
be available.

Reviewed-by: Dan Williams <dan.j.williams@intel.com>
Signed-off-by:  NeilBrown <neilb@suse.de>
NeilBrown 14 سال پیش
والد
کامیت
3a6de2924a
1فایلهای تغییر یافته به همراه3 افزوده شده و 0 حذف شده
  1. 3 0
      drivers/md/raid5.c

+ 3 - 0
drivers/md/raid5.c

@@ -1796,6 +1796,9 @@ static void raid5_end_write_request(struct bio *bi, int error)
 		if (!uptodate) {
 			set_bit(WriteErrorSeen, &rdev->flags);
 			set_bit(R5_WriteError, &sh->dev[i].flags);
+			if (!test_and_set_bit(WantReplacement, &rdev->flags))
+				set_bit(MD_RECOVERY_NEEDED,
+					&rdev->mddev->recovery);