drm/omap: panel-sharp-ls037v7dw01: Add note for incorrect data drive edge

According to the datasheet of the panel, both data, DEN and sync signals
are expected to be driven on the falling edge of the DOTCLK.

Signed-off-by: Peter Ujfalusi <peter.ujfalusi@ti.com>
Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>
Peter Ujfalusi 9 年之前
父节点
当前提交
3a3caf305f
共有 1 个文件被更改,包括 4 次插入0 次删除
  1. 4 0
      drivers/gpu/drm/omapdrm/displays/panel-sharp-ls037v7dw01.c

+ 4 - 0
drivers/gpu/drm/omapdrm/displays/panel-sharp-ls037v7dw01.c

@@ -52,6 +52,10 @@ static const struct videomode sharp_ls_vm = {
 	.flags		= DISPLAY_FLAGS_HSYNC_LOW | DISPLAY_FLAGS_VSYNC_LOW |
 			  DISPLAY_FLAGS_DE_HIGH | DISPLAY_FLAGS_SYNC_NEGEDGE |
 			  DISPLAY_FLAGS_PIXDATA_POSEDGE,
+	/*
+	 * Note: According to the panel documentation:
+	 * DATA needs to be driven on the FALLING edge
+	 */
 };
 
 #define to_panel_data(p) container_of(p, struct panel_drv_data, dssdev)