Просмотр исходного кода

sx8: use real time for the command seconds

Commit 8182503df1ba used monotonic time, but if the adapter is
using the seconds for logging entries, then we'll get duplicate
entries if the system is rebooted. Use real time instead.

Reported-by: Arnd Bergmann <arnd@arndb.de>
Fixes: 8182503df1ba ("block: sx8.c: Replace timeval with ktime_t")
Signed-off-by: Jens Axboe <axboe@fb.com>
Jens Axboe 10 лет назад
Родитель
Сommit
39fc8830eb
1 измененных файлов с 1 добавлено и 1 удалено
  1. 1 1
      drivers/block/sx8.c

+ 1 - 1
drivers/block/sx8.c

@@ -673,7 +673,7 @@ static unsigned int carm_fill_sync_time(struct carm_host *host,
 {
 	struct carm_msg_sync_time *st = mem;
 
-	time64_t tv = ktime_get_seconds();
+	time64_t tv = ktime_get_real_seconds();
 
 	memset(st, 0, sizeof(*st));
 	st->type	= CARM_MSG_MISC;